sanborn B51 A24 80V1 compressor hard or no start

by mark .
(bloomington , mn)

Tank would stop filling at 75 psi.


Did a lot of air grinding one day and compressor continually ran, Eventually it would not restart.

Looked at magnetic starter and some of the fuses were burnt. Screws were loose. Ordered a new magnetic starter, started compressor, ran for 5 minutes then died. Would not start.

Installed new pressure regulator, would still not start.

Removed motor and brought it to a compressor shop to have them test it. They said it was good. Reinstalled, would not run. Removed motor and brought it to a electric motor repair place. they disassembled and cleaned, hipot test the winding ,repaired the starter switch and tested. Reinstalled motor. Ran for 2 minutes about half normal speed and stopped.

Now it has faint humming sound from motor when I flap breaker to turn it on.

Comments for sanborn B51 A24 80V1 compressor hard or no start

Click here to add your own comments

Sep 06, 2018
If the motor caps checked out...
by: Doug in s.d.ca.

then your second stage valves are probably failed.

Good luck.

Sep 05, 2018
sanborn B51 A24 80V1 compressor
by: Bill

Mark, did anyone check the motor capacitors?

Click here to add your own comments