Compressor blowing air out of start valve

by John Larysz
(Naples, NY)

I have a Central Pneumatics 21 gallon vertical air compressor- I think it is model 61454.


Just about everything has gone wrong with it; it is made to be cheap, not good.

I've replace the pressure switch and the check valve, and it is working now but it won't reach working pressure - it reaches about 80psi and then just keeps on running.

There's a lot of air blowing out of the cold start valve. Is this normal? It doesn't seem right to me!

Comments for Compressor blowing air out of start valve

Click here to add your own comments

Jan 30, 2019
Cold start valve
by: Doug in s.d.ca.

Normal? No.

Is it in the cold where it could be frozen open?

If not, you can R&R, try cleaning. Otherwise, you can usually just plug it. If it then has trouble restarting, you'll need to replace it.

Good luck! Let us know it goes, please.