Clarke SHHH 100-50 stopped filling the tank

by Bri
(UK)

Clarke SHHH 100-50

Clarke SHHH 100-50

Clarke SHHH 100-50
Clarke SHHH 100-50 pumps

My Compressor has stopped filling the tank, and is blowing smoke from the Air intakes!


Ive checked the non return valves and all seem correct and functioning but im at a lose as to why its suddenly stopped filling the tank, gets to about 20psi and thats it.

Ive always used clarke Oil and levels are correct, the other thing is that when i checked the non return valves they were full of oily water!

there are no leaks in the system and ive always owned the compressor and its worked fine until now.

Today i started it from cold and it filled the tank, then when i started to use it, after the motors kicked back in it wont deliver any air to the tank.

It also takes a lot longer to fill tank from cold than it used to.

Comments for Clarke SHHH 100-50 stopped filling the tank

Click here to add your own comments

May 08, 2018
Head gaskets for Clarke SHHH 100-50?
by: Bri

Intake filters in place and all check valves cleaned and replaced as needed. think the head gaskets are suspect, but havent had one of these pumps apart yet so any advice welcomed on replacing the head gaskets.

May 04, 2018
Clarke SHHH 100-50 stopped filling
by: Doug in s.d.ca.

Did you check the intake air filters?

You cleaned out the check valves, right?

And you do drain the tank regularly, right?

Any change in the power supply? You might verify the voltage while it's running.

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Clarke Air Compressor Issues.