Air continues to leak from control line orifice, replaced control pressure regulator and shuttle valves did not help. Any suggestions

Comments for Air Leaking from Control Line Orifice Constantly

Click here to add your own comments

Jan 26, 2018
Air Leak Advice from 40 year compressor guy
by: Bill

Thank you for taking the time to share your info in a few posts on this site. It's much appreciated.

Jan 25, 2018
Air leak
by: 40 year compressor guy

Air leaking back in the control air line can be from the control solenoid or from the blowdown valve. If you replaced the regulator and shuttle valves but none of the control solenoids,that may be your issue.

How I trouble shot the issue is to start removing the control lines. Some will have air some will not. The one that has air and shouldn't leads you to the problem. The experience comes in knowing which lines have air and which do not. A good tech should have your problem solved in 20 minutes or less.

There are other issues going on and a visual check of how the control system is operating is another indicator of the problem. Good luck

Dec 23, 2017
Air Leaking
by: Doug in s.d.ca.

Yes. To help us help you, tell us what model of compressor you have beyond it just being a Sullair.

Click here to add your own comments