2012 doosan c 185 won't run under load

by sabrina
(lexington nc)

2012 doosan towable air compressor c185 will run for hours while not under a load when under a load the machine will run for about 30 minutes. I have changed all fuel filter and check coolant & air filters.

Comments for 2012 doosan c 185 won't run under load

Click here to add your own comments

May 24, 2018
Dusan C 185
by: ICS

Sounds like it may be shutting down on hi temperature. Check the oil level in the compressor part of it. It may be low on oil, or have a bad thermostat. Check oil temps in and out of oil cooler. You should see a 30 degree drop, give or take a few degrees. If the oil level is OK, and the thermostat valve is opening and allowing oil into the cooler, then it may be your temp sensor.

May 23, 2018
dies under load
by: Doug in s.d.ca

How? Slow to a stop, just quit as if turned off?

No control panel indications?

Assuming it's reasonably level, are the radiators working and not blocked? Fans?


Click here to add your own comments