Why does my compressor keep running ?

by ron tapp
(grass valley, CA)

My pancake compressor keeps running even after the hose is disconnected. I cannot detect any leaks.






Bill answers...

Howdy Ron.

Disconnecting your air hose from the compressor doesn't shut your air compressor off.

What shuts it off is the pressure switch.

If the pressure in your compressor tank exceeds the pressure level that it normally used to shut off at, then you have a failed pressure switch.

This can be dangerous. Get the problem fixed as soon as you can.

Cheers,

Bill

Click here to post comments.

Join in and write your own page! It's easy to do. How?
Simply click here to return to Has pressure switch issue
.