We have Quincy compressor showing dewpoint fault and air is blowing out of the "water" valve

The Quincy compressor registered a "dewpoint fault" and air is blowing out of the "water" valve. Please advise.
__________________

OK, I know what dewpoint is, but I'm hanged if I know how your compressor is registering a "dewpoint fault", and I'm not quite sure what you mean by a "water valve".

I would very much like to offer a suggestion, but I'm afraid I just don't understand.

Maybe you could send in a digital photo of where the problem is occurring?

Sorry,

Bill

Comments for
We have Quincy compressor showing dewpoint fault and air is blowing out of the "water" valve

Click here to add your own comments

Apr 02, 2011
air dryer...
by: Mike

Dewpoint - Sounds like your compressor has an integrated refrigerated air dryer. If you have a dewpoint fault check the following: Does the dryer fan turn freely by hand? If not, replace. Check the control fuses in the dryer circuit. If any are blown, replace. Also check the pressure switch in the dryer. It may have a manual reset button on it, if so press it. If you still have a problem call a refrigeration tech. You might have lost freon or refrigeration compressor has failed. Always keep your dryer condenser free from dirt. Blow it out once a week.
'Water" valve - Your dryer has either a float type drain or a timed solenoid drain that removes water from the dryer. Your drain is stuck in the open position. Either open it up and clean it or replace it.