UST 1110c compressor will not restart.

by Kira

We have another of these model 1110c exactly like the pictured one from the not pressurizing past 50 psi question.

We're in the process of building garden boxes and the damned thing just will not cut back on.

We've trouble shot the power and found no problems.

We've let it sit and cool down for over an hour. Still not restarting.

It has a "circuit breaker" button on the side, but so far as i can tell it doesn't reset anything. Very frustrating. We were almost finished. Please help!

Aggravated in Atlanta

Comments for UST 1110c compressor will not restart.

Click here to add your own comments

Apr 24, 2016
by: Kira

Ok. So, being an electrician has it's benefits. I took the switch housing cover off and found out that it's spring triggered and our spring had come off. I pulled the spring back into place and voila! It works again. Thanks for having a look and I sincerely hope this might help someone else out there.


Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to UST Air Compressor Issues.