thomas - 2hp oil less 120 vac. starts, runs, cuts out a 60 psi

2hp oil less 120 vac. starts, runs, cuts out a 60 psi. Should be off at 120 psi. Replaced pressure switch same results.

_________________________
Bill says...

If it's not the pressure switch, then have you considered that maybe it's the pressure gauge that's pooched?

How have you been checking the cut out pressure level?

Bill

Comments for
thomas - 2hp oil less 120 vac. starts, runs, cuts out a 60 psi

Click here to add your own comments

Jul 11, 2011
2 hp thomas
by: ed

Pressure switch and gauge are new, also check pressure with air gauge at end of a short air line.

Thank you for your input.

Ed

_______________________

Ed, how is it cutting out? Is the pressure switch tripping it off, or is it the overload on the motor, assuming there is one?

I assumed the former. If the latter, then it may be a run capacitor (if one used) not being able to keep up with the increasing load, or it's possible motor wear cause the same problem.

Bill