Sullair ES8 Runs well but does not stop

by Marc
(NJ)

Recently purchased ES8 30hp model with no manuals. tried to set it up on my own but cant figure how to set it on auto. I need my compressor to stop at 120 and run again at 95psi. Called in technician who said that this model needs to run all day. Its hard to believe that i got the compressor that will make noise for 8 hours each day.

Does anyone know how to set on and off feature or maybe have access to owners manual? Thank you

Comments for Sullair ES8 Runs well but does not stop

Click here to add your own comments

Dec 01, 2015
Sullair ES8
by: Bill

According to the manual, which you can easily find online, the following applies to your compressor:

AUTOMATIC OPERATION
For applications with varied periods of time whenthere are no air requirements, Supervisor’s AUTO-MATIC mode allows the compressor to shutdown(time delayed) when no compressed air require-ment is present and restart as compressed air isneeded

If it is not set on automatic operation, yes it will run continuously and load and unload the compressing of air as demand is there, but the motor will continue to run.

Loud, hmmm?

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Sullair Air Compressor Issues.