Speedaire dayton 4b227 blowing fuses
by Mark
(Pickering)
Greetings Bill, All,
When the tank is empty turn it on no problems fires up and runs great let the tank get too full and it will trip the breaker, anything over 80lb pressure in the tank. Try to start with a pressure in the tank over 40lb and it trips the breaker. I pulled the unloader valve and it's working fine, so went for the tank check valve and although very rusty outer case appears to be working fine. So nothing seized the breaker on the motor doesn't pop only my main breaker. I have tired a stand alone 15a outlet with the same results. Although it did get all the way to a full tank on the stand alone outlet. Am I dealing strictly with a power delivery problem or something else. Any help or suggestions would be greatly appreciated
__________________
Bill says....
Good on you for doing the checks you did, and for telling us all what steps you've taken so far.
Unless you have a mechanical issue overloading your motor, based on what you are saying, and the trend to flowing the breaker when the back pressure in the tank rises, I would suggest you next check out the capacitor. If it isn't performing, as your tank pressure grows, so too does the load, and the compressor may be relying on the added power supply from the capacitor that isn't there now, hence it pulls too much current and pops the breaker.d
Good luck, and keep us all posted if you would.
Cheers,
Bill