sip 200 litre compressor blows reset before tank is full

by dan
(bellaghy,co derry)

SIP air compressor

SIP air compressor

sip 200litre 1 phase (red colour)compressor 3hp

i have replaced reset button,capacitor and pressure switch.

however this occur irregularly and is annoying as i use compressor to feed air supply to air feeders and vaccum gates in dairy miling parlour
____________________
Dan, a typical reason for the reset letting go before the tank is full to cut out pressure is one of power.

Either not enough power is being delivered to the air compressor from the power source (other things draining power at the same time - too small power line - too long power line etc.) or, as the backpressure increases from the tank the load increases and the run capacitor has weakened. That or the motor itself is wearing out.

I have no idea how old your SIP air compressor is so you'd be a better judge if it's old enough to have things wearing out.

Bill

Comments for sip 200 litre compressor blows reset before tank is full

Click here to add your own comments

Feb 03, 2014
sip
by: dan

thank u

_______________

:-)