prv valve blows after its full

by kevhash
(los angeles)

I have a speedaire 5f237a.


It works fine at first but after about a 1/2 hour of use the prv valve blows. not sure what the problem is.

should i replace something?





Comments for prv valve blows after its full

Click here to add your own comments

Oct 03, 2016
PRV releasing
by: Bill

Howdy Kev... what's the pressure in the tank when the PRV lets go?

If it's lower than the cut out pressure of your compressor, replace the PRV.

If it blows since the air pressure in the tank is higher than the normal cut out pressure, it's likely your pressure switch.

If the pressure is so high your PRV is letting go, that's dangerous. Get it fixed fast.