Mystery Air Loss - runs and puts no air into the tank and guages read "0"
by Dick Jenkinson
(Columbus Ohio)
Magnum dual cylinder (5 hp - HA!) 35 Gal Tank.Has run perfectly for 5 years.
Changed the oil yesterday now the air is disappearing.
I can't hear a leak.
Compressor runs and puts no air into the tank and guages read "0".
Did not run it long enough for pressure switch to trip but thermal circuit breaker did.
Adjusting the two limiter switches makes no difference. Problem probably in pressure switch (leaking ??) Any advice ??
________________________
Bill says...
Dick, dump any air from the tank with the compressor off. Pull the line from the top of the pump that runs down into the tank,
Start the compressor.
Is air coming out of the pump? If there is air coming out of the pump, can you stop that air by putting a gloved finger over the outlet hole?
Post a response here, if you would.
Cheers,
Bill