My Central Pneumatic compressor model 94667 shuts off at 105psi and not at the 115psi it is rated for.
by Brian
My Central Pneumatic compressor model 94667 shuts off at 105psi and not at the 115psi it is rated for.
__________________________
Bill says...Yup, sure sounds like a failing pressure switch.
The diaphragm that reacts to the changing air pressure in the switch alternatively pushes against, or relaxes from a spring. When the pressure settings for the switch are adjusted (if they are adjusted) the spring pressure is actually what is changed.
Unless you have made a change to the pressure settings yourself, I surmise that either the diaphragm or the spring has changed, and this is allowing the switch to trip at the lower cut out pressure setting.
It were me, I'd change the switch.
Cheers,
Bill