It cut off right after I turn it on

by Yaogen Dong
(Chicago, IL.)

I think that there is electrical short somewhere with my compressors because it cuts off right after I turn it on and it shuts down the electricy of the power line in the house.


________________________
Bill says...

Yaogen, is there pressure in the tank when you try to turn it on, or is the tank empty?

When you turn it on, does it try to start - any noise from the motor - or does nothing happen, and the breaker pop or fuse blow?

If there is air in the tank, open the tank drain to drain it to zero. Close the drain and try to start the compressor. Any change?

Please post your answers as a comment here.

Cheers,

Bill

Click here to post comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Electrical-troubleshooting-compressors.

AIR COMPRESSOR shuts off every 10 minutes...

After about 10 minutes of running it shuts down, then I have to wait about 15 minutes before it'll turn back on, any help would be appreciated, thanks
_______________________
Bill says...

I don't know what type of air compressor we are talking about, but from your description, it sounds to me as though your unit is going off on thermal overload, as opposed to it being strictly an electrical problem.

You might want to have a look at the page entitled Duty Cycle, linked from the site map page.

It explains the phenomenon I think you are experiencing.

Cheers,

Bill

Click here to post comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Electrical-troubleshooting-compressors.

My compressor fills up fine but when it goes to refill motor switches off

My compressor fills up fine but when it goes to refill its self the motor turns on then turns off. I let it sit for a little while then it works.
___________________________________

Hello there. Yes, this is a weird one!

When your compressor has been sitting unused and you plug it in or switch it on, it starts and runs fine up to cut out pressure. Then, when you have used some air to the cut in pressure point, your pressure switch trips, the motor starts, then stops, and you wait for a while, and then it starts again?

I need a bit more info to try and help;

~ How long from the motor turn on to the motor turn off?
~ How long do you wait before the compressor starts properly?
~ When the compressor reaches normal cut-out pressure, do you hear it unload?
~ Can you feel the motor to determine if it's excessively hot after filling the tank the first time?
~ How does the motor shut off? Does the pressure switch trip again, or is it still calling for air and the motor just stops?

It might be start capacitor problem or could even be a pressure switch issue, but I'm not absolutely confident at this time. If the motor gets too hot, it might be a thermal overload with an auto reset issue.

Cheers,

Bill

Comments for My compressor fills up fine but when it goes to refill motor switches off

Click here to add your own comments

Feb 15, 2011
I Have the same problem
by: Blaine Meyer

My compressor has a similar if not the same problem. It starts fine ad fills the tank to the proper pressure. When the pressure drops it refills one or two more times. After that the motor seems to be loping, starts for a second and then stops. I just replaced the pressure switch the other day the problem is the same as it was before the pressure switch was replaced. I also checked and cleaned the Check valve which looked pretty clean. Ant ideas ?

________________________

Look to the start capacitor or motor.

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Electrical-troubleshooting-compressors.

Air compressor won't start

by Steve Dillman
(Fort Wayne IN)

My Ingersoll Rand 5hp230V single phase two stage compressor won't start. Has been in production for 5 1/2 years with no problems. Came into shop and found it caused the dedicated breaker to trip. I reset and buzzing noise at compressor caused me to shut it off. I installed a new pressure switch and problem did not change. I can manually turn the flywheel. I took off the belt to motor and with juice turned on , it powers up and turns just fine. I tore the motor( mechanical pump) off and everything seems fine. No problem with pistons , cylinders or shaft. I don't want to press bearings out unless that seems like the solution.
Any ideas before I reassemble? I didn't fix anything during the teardown, so I assume the problem is still there.

_________________________
Bill says...

In order for your compressor to start with any kind of load, the motor needs a boost from an electrical starter or capacitor.

The buzzing sound suggests to me that it's this part of the motor start process that has failed.

Without the starter / capacitor, if there is any load, when the motor tries to start, it pulls more amps than the circuit has available, and pops the breaker.

That's where I would look next.

Cheers,

Bill

Click here to post comments