my 2 stage compressor hit the cut out-165psi then shut down and tries to restart thus blowinf the breaker

by greg
(granite falls,wa)

its an westinghouse v-twin 2 stage with a remote 80 gal tank. check valve or pop off mounted to the tank with a 1/4 copper line running back to the pressure switch, 220 volt on a 20amp breaker 16 amp draw from the motor. switch says cut in at 145 with cut out at 175 needs to be adjusted I know but seems it should shut off with out trying to restart 10 seconds after shutdown. Compressor is a westinghouse model 2VC-1 any diagraghms on plumbing this thing-- on the inlet side,tank to pressure switch etc e-mail me at gregvan2008@myway.com thanks hope you can help

____________________________
Bill says...

Greg, I hope someone reading this has the diagrams or schematics you are looking for.

If your compressor is trying to start 10 seconds after reaching cut out pressure, and assuming that the tank pressure is still above the cut in pressure setting, then I would suspect your pressure switch is at fault, unless something in the line is preventing the tank pressure from registering on the pressure switch diaphragm.

If the compressor stops at the cut out pressure point, does it unload? You should be able to hear it. If it doesn't, and it tries to start against pressure over the piston(s), that's likely why it it is blowing the breaker on attempt-to-start.

Cheers,

Bill




Comments for
my 2 stage compressor hit the cut out-165psi then shut down and tries to restart thus blowinf the breaker

Click here to add your own comments

May 20, 2010
cut out
by: Anonymous

thanks bill I think you are right its nopt unloading and that is part of the problem -gonna replace the switch and do a bit of plumbing re-work

Click here to add your own comments