Makita MAC2400 will not build pressure

by Ted Haase
(Bluffton,SC)

Makita MAC2400 I was given this compressor, friend said the unloader tube and fitting that attaches the tube to the check valve was missing.


I ordered the two parts,replaced them.

The compressor runs but will not build pressure. If I block the end of the unloader tube the machine builds air,shuts off at about 130#'s and restarts at about 80#'s.

I see no reason for that unloader tube. What am I missing? Thank you,Ted

Comments for Makita MAC2400 will not build pressure

Click here to add your own comments

Mar 07, 2015
Leaking
by: Doug S.D.Ca

See the "Pressure Switch Leaking" section...

Mar 06, 2015
Makita MAC2400 will not build pressure
by: Bill

Check and see if the tank check valve is leaking.

Bill

Click here to add your own comments