Line to the pressure switch keeps blowing off

by Eddie Cimini
(Grove city ohio)

I have a charge air pro 5hp / 20 gallons. The little rubber hose going from the metal air inlet line to the pressure switch keeps blowing off at 80lbs of pressure. The compressor just keeps running blow air out. What do I need to change to make it stop?

Comments for Line to the pressure switch keeps blowing off

Click here to add your own comments

Mar 29, 2016
Return line to pressure switch keeps blowing off
by: Eddie C

Cutting 1/2" off the end worked. It went straight to 120psi them shut off. Thanks.

(You are most welcome... Bill)

Mar 29, 2016
line to the pressure switch keeps blowing off
by: Bill

I suspect that the existing line is heat-hardened and as such, cannot maintain the connection.

I think on this compressor the air line runs into the bottom of the pressure switch?

If so, cut about 1/2" off the air line where it enters the switch after the next time it blows out. See if that solves the problem.

If not, replace this line.

Click here to add your own comments