Kaeser membrane dryer frequent failure

by Juma

Kaeser membrane dryer

Kaeser membrane dryer

Hi every one

In my company we are using the below types of Kaeser air compressors:
ADS 32 S
DSD 171 S
BSD 72 S

All of them have same problem; membrane dryer purge air increased (3 months after replacement) leads to high DP across the dryer line.

And these dryer elements supposed to be changed every 3 years.

So can anybody give me a solution for this problem?

Thanks and regards

Mechanical work preparer

Comments for Kaeser membrane dryer frequent failure

Click here to add your own comments

Jul 17, 2016
Membrane dryer failure
by: Bill

If you go to the Kaeser site you can download information on their membrane dryers.

All of the membrane dryer models on the Kaeser site I found have an upper inlet temperature of 100 degrees F. That is 38 degrees C.

I suspect your inlet temps are too high at 50 degrees C, contributing to the membrane failure.

Jul 14, 2016
by: Doug in s.d.ca


So, what's between the pumps and these dryers?

another dryer? filters? or just pipe?

If you don't have filters, you probably need to add some.

Jul 14, 2016
dryer parameters
by: Juma

Inlet pressure: 8-10 bar
Temperature: 45- 50 C

Jul 11, 2016
Membrane dryers
by: Doug in s.d.ca

What's the temperature at the inlet to the membrane dryer stack? What is the Pressure there too?