Jun air 6 compressor not starting

by Muhammad

Jun air 6 compressor, not starting, current and wires are okay.

Jun air compressor model 6 15 liter capacity. Suddenly stopped working but once started when tried.

Again the same problem now it is not responding what can be possible issue what should i check???

Comments for Jun air 6 compressor not starting

Click here to add your own comments

Jun 01, 2016
Thank you Bill.
by: Anonymous

You are right the current was not passing to the motor when i connected it directly to it it started. Thank you very much.

(You are welcome, Muhammad)

Jun 01, 2016
Jun Air not starting
by: Bill

When you say current and wires are OK, did you check the flow of power on the motor side of the pressure switch when the tank pressure level was below normal cut in?

If power isn't passing the switch in that circumstance, it is the switch that is likely at fault.

If power is passing the pressure switch and the motor is not starting, my next check would be the viability of the motor start capacitor.