I receive all the time the message MOTOR on SM11?

by Paul Muresan
(Bucharest, Romania)

Hi ! I have an SM11 Kaeser compressor. I've done the commissioning but I receive all the time the message MOTOR and I can't reach the running condition. Has somebody a solution for this ? Thanks

Comments for I receive all the time the message MOTOR on SM11?

Click here to add your own comments

Feb 09, 2017
Motor?
by: Carl

Hi, these are 3 phase machines, im guessing that it is new to you? So try swapping 2 of the wires going into the machine from your isolator, try that, it does sound like it is trying to run the wrong way round.
Which controller do you have? Sigma or Kaesar controller? (Kaesar is the little black one with 4 LEDs) Let us know how you get on.

Feb 08, 2017
message: MOTOR on SM11
by: Doug in s.d.ca.

http://www.kaeser.com/int-en/company/about-us/kaeser-worldwide/locations/romania.aspx

may be able to help.

Are you running it on 230 or 400V?

If 400, is it running in the right direction?