air compresser kicks breaker when shut off on automatics

Comments for campbell hausfeld kicks breaker

Click here to add your own comments

May 07, 2015
campbell hausfeld kicks breaker
by: Bill

Not completely unusual Ed.

See the troubleshooting page about why air compressor pop the breaker.

If that doesn't help, add a comment here with the model number, and what you checked, and we'll press on.

Bill

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Campbell Hausfeld Compressor Issues.

HJ300200 sometimes will pump up to 150, other times only 40.

by Ed Sapp
(Wileyville, WV)

Campbell Hausfield HJ300200 sometimes will pump up tp 150, other times only 40. It holds pressure when left off. Is there a check valve where the braided line comes off the compressor motor that could stop the air from getting to tank. Would the piston still be since it will pump to 150, maybe just bad valve reeds. It is only a year or so old and not used a lot.

Comments for HJ300200 sometimes will pump up to 150, other times only 40.

Click here to add your own comments

Mar 17, 2015
Campbell Hausfield HJ300200
by: Bill

Usually, if the cut out pressure varies, it's the pressure switch that's the culprit.

Any other issues besides the changing cut out pressure, Ed?

Bill

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Campbell Hausfeld Compressor Issues.

Model HJ300200 portable compressor shuts down before cut out PSI

by Toby Williams
(Temple, Tx USA)

I have the 200psi upright. About a yr old.

This problem started within 6 mo of buying it. Should have taken it back but didn't.

I can turn it on and it runs until it starts to get warm then dies. I can wait a little while with the power switch off and then it will start again.

Takes forever repeating this process to get it to fill and shut off.

Then sometimes it won't auto start when pressure drops if it was just running.

Comments for Model HJ300200 portable compressor shuts down before cut out PSI

Click here to add your own comments

Aug 25, 2015
shutdown
by: Doug in s.d.ca

You might as well check the caps, too, especially if this started (at 6 mo) and nothing external to the machine changed.

Possible infant failure of cap or wire(s) came loose.

Aug 24, 2015
Compressor dies before filling
by: Bill

Sounds like it's going off on thermal cut out, Toby.

Tell me a bit about how you've got it plugged in, what amperage the breaker or fuse you've got on the circuit, if you are using a power bar, that sort of thing, K?

Bill

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Campbell Hausfeld Compressor Issues.

HJ300200 circuit breaker trips after 1 minute of use

by Mike
(Spring)

Campbell Hausfeld HJ300200 will run for a minute or two and then stop.

Turning power switch off for a minute and then on restarts the pump, but shortly after it stops again.

It takes 4-5 cycles to fully pressurize the tank to 200psi.

I have it plugged into a dedicated 20A circuit, directly into wall outlet.

I changed the pressure switch, with no change to the problem.

I don't see any parts on the diagram other than the motor that would seem to fix it.

For the price of a new motor, I'd be tempted just to buy a new compressor.

Any help would be greatly appreciated

Comments for HJ300200 circuit breaker trips after 1 minute of use

Click here to add your own comments

Aug 30, 2015
HJ300200 circuit breaker trips
by: Bill

See the troubleshooting pages for ones referring to air compressors that pop breakers. There are things to check.

Add a comment here telling us what you found, if you wish.

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Campbell Hausfeld Compressor Issues.