GA7 VSD+ FF shows element outlet temerature high

GA7 VSD+ FF shutdown. shows element outlet temerature is high.


The fan motor is not running though it seems to be " running" on the display > fan motor

Comments for GA7 VSD+ FF shows element outlet temerature high

Click here to add your own comments

Oct 16, 2015
Check fan
by: Carl

You need to see if there is voltage going to the fan when it clicks in. If you know you have voltage going to it, then you know it should be running,
Also check the oil level and clean the cooler.

Oct 16, 2015
outlet temp
by: Doug in s.d.ca

I'd be looking at whether the fan running indication means it's actually running or just enabled to run.

Maybe disconnect the fan and see if the panel indication changes.