GA160 air compressor shuts down on "element outlet"

by S. Philliips
( Colorado US.)

Compressor shuts down on "element outlet" fault. Temp. shoots up immediatly after startup. Oil is good and coolers have been cleaned. Cooling fans start up then shut off after a few seconds.

Comments for GA160 air compressor shuts down on "element outlet"

Click here to add your own comments

Mar 23, 2016
Part 2 to this question
by: Anonymous

what is the ideal ohmic value when checking the temperature sensor? Manual does not say...

Jun 11, 2015
Oil lines
by: Anonymous

Oil stop valve

Apr 18, 2015
Oil lines
by: Carl

Check all your oil pipes and hoses, your air end seems to be not getting oil into it, remove all your pipes one by one and make sure theyre clear, failing that, check the temperature sensor, it could be faulty

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Atlas Copco Compressor Issues.