GA 160 VSD expansion module failure

by Byran Boyle
(Houston, Texas, USA)

GA 160 VSD


The compressor will still run through a round about way.

Must put it in LAN mode and the green run light comes on then switch to local and hit the start button and it runs. Works once running in local or LAN.

But Expansion module fault will not reset..

Comments for GA 160 VSD expansion module failure

Click here to add your own comments

May 31, 2017
expansion module failure
by: Doug in s.d.ca.

The LAN expansion module?

If you haven't already, try removing and replacing it.

Is it actually connected to a LAN?

If the R&R doesn't solve it, then maybe it's actually bad.

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Atlas Copco Compressor Issues.