Craftsman compressor motor runs quiet and then trips breaker

by Dave
(Calgary)

I have a Craftsman 20 gal. oil less compressor.


It will start and run for about 15 seconds and then throw the breaker .

nothing else is on the line and it's been working fine in the same location for a year.

When it starts the motor is much quieter than normal but looks to be running fine .

Don't know if it's relevant but after it shuts down if I turn the power switch to the off
position there is air bleeding from the pressure switch area .

_________________
Bill says...

Dave, on my compressor I can't hear the electric motor running while the compressor is running. What I hear is the compressor pump.

Are you hearing a quieter motor, or a quieter pump.

Good that you have clean power to the compressor. That is often a culprit.

When it runs for the 15 seconds, is pressure rising in the tank? If so, it would lead me to think that you have a compressor motor capacitor issue. If no pressure visibly rising, might be a pump issue.

As to the leak out of the pressure switch area, it's likely your unloader valve that is leaking air, and that is happening because your check valve is probably not seating correctly. Pages of info on both are linked from the site map.

Keep us posted as a comment here, please.

Cheers,

Bill

Comments for Craftsman compressor motor runs quiet and then trips breaker

Click here to add your own comments

May 26, 2011
Thanks
by: Anonymous

Thanks
Quieter pump. I just lumped the whole mechanical end together
Motor run capacitor seems to be the problem. Never thought of it.
Goggled my symptoms and capacitor and get a pile of hits.
We will never know for sure .
Tried to get parts from Sears and after some odd reactions they replaced the
compressor as it was just out of warranty.

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Craftsman Compressor Issues.

Air in the tank but not making it to the quick connect.

by Brian
(Bordentown, NJ)

New Craftsman 33 Gal. 1.6hp vertical air compressor.

Followed the initial start up instructions.

then shut the tried to use the compressor.

The tank fills, there are no leaks but when I attach a hose or tools nothing happens. It feels like the air is"nt making it to the quick connectors.

_______________
Bill says...

Brian. Please post your response as a comment on this thread.

What is the pressure reading on the regulator gauge please?

Thanks,

Bill