IR model ssr-ep150 rotary screw inlet control system?

by mike
(ohio)

we had an issue with the inlet control system the butterfly valve would not close we replaced the starter control board,stepper motor and the limit switch board


now when we power up the valve closes to the unload position which it should and we a ready to start display when we start it the butterfly valve starts to open and shuts down the compressor and displays check motor rotation

this compressor has been in service for 5 yrs and none of the three phase lines has been changed

i'm not sure but i think theres a pressure sensor 0-15psi which is located after the butterfly valve this sensor i think senses a vacuum to let the system know the correct rotation if its bad it could give you a false indication

any thoughts or any other solution you may have would be greately appreciated is there any way of testing these sensors or verifying this thx

Click here to post comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Ingersoll Rand Air Compressor Issues.

Minimum RPM on a 223x5 Compressor

by Dave

Ingersoll Rand model T30 (Photo: www.ebay.com)

Ingersoll Rand model T30 (Photo: www.ebay.com)

Can you tell me how this number is determined and what happen if you don't run at this minimum or faster? Thanks
__________________
No idea Dave. Hopefully a more informed visitor will post a reply for you.

Bill

Click here to post comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Ingersoll Rand Air Compressor Issues.

How to reset running hours air compressor ingersoll rand

by ahmad
(indonesia)

i want to reset running hours air compressor ingersollrand how to working in display plse hlp me.if u have picture display pls send to me..thx


Click here to post comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Ingersoll Rand Air Compressor Issues.

Reset the High Temp IRN30 alarm?

by Emil
(Commerce CA)

I have A compressor IRN30 (TAS) and it is working fine , but one time it give me a high temp Alarm and it wouldn't start again even after I service it , I think it need to reset the Alarm , so how to reset the Alarm and is it need a service password?!!

Click here to post comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Ingersoll Rand Air Compressor Issues.