compressor fills with air... when time tom refill motor will not run

by Kelli
(MI)

COmpressor wont run after first air fill

_______________________
Bill says...

Won't run after first fill, as in, you are using some air, pressure drops to the cut in level, and the compressor will not start?

First thing to do is drain the air from the tank to zero PSI, and then start the air compressor again.

Starts OK?

After the pressure reaches cut out, monitor the UNLOADER VALVE to be sure it operates. If it does not, that is likely your compressor problem.

Post a comment here with any more questions.

Cheers,

Bill

Click here to post comments.

Join in and write your own page! It's easy to do. How?
Simply click here to return to Compressor Blows Breaker
.