Compressor builds pressure then does not come back on.
I have a Husky 26 Gallon compressor that builds to 50 psi then shuts off and will not come back on.
_______________________
Bill says... Hello Nathan:
Why is the compressor shutting off at 50 PSI? Normally general purpose compressors have a high pressure set point of 120-170 PSI, sometimes higher.
If you normal pressure cut out level is over 100 PSI, and your compressor is shutting off (not blowing a breaker) at 50 PSI, then the switch has failed. Replace it.
Cheers,
Bill