Compressor builds pressure then does not come back on.

I have a Husky 26 Gallon compressor that builds to 50 psi then shuts off and will not come back on.

_______________________
Bill says...

Hello Nathan:

Why is the compressor shutting off at 50 PSI? Normally general purpose compressors have a high pressure set point of 120-170 PSI, sometimes higher.

If you normal pressure cut out level is over 100 PSI, and your compressor is shutting off (not blowing a breaker) at 50 PSI, then the switch has failed. Replace it.

Cheers,

Bill




Comments for
Compressor builds pressure then does not come back on.

Click here to add your own comments

Jan 28, 2011
Compressor builds preasure to 100lbs
by: Troy B

Compressor builds preasure to 100lbs then cut off and will not come back on till 0 Lbs if i hit the swtch to make it come back on it blows breaker .Is this a preasure switch ?

_________________________

Have a look at the Unloader Valve page linked from the Valve page. If your unloader valve isn't working, that could overload the motor and cause a popped breaker. It starts at 0 PSI because the pressure over the piston has vented enough.


Click here to add your own comments