6100ah controller showing fault shutdown oil filter change?

by ashwath
(india bangalore)

hi i have model 6100ah compressor and sure scan controller contrller showing fault shutdown oil filter change due compressor not start how to correct plese help

Comments for 6100ah controller showing fault shutdown oil filter change?

Click here to add your own comments

Sep 10, 2015
faults
by: Joe

Hi...we have a CompAir L120SR.this machine is showing a shut down fault.The fault is sr motor speed exceeded speed.Can you guys tell me how to clear the fault. I tried reset that does not help.

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Compair Compressor Issues.

Compair L120SR showing "start inhibited"

by pete scott
(york)

L120SR is showing fault shutdown and will not reset just shows message "start inhibited" but cannot clear or reset this

_______________

Pete, that's a control override problem, and not something that I can even try to diagnose from afar.

I'll post this in the hope a Compair person reads it and offers a suggestion, but I think you either have to get Compair help or a local service company that fixes them.

Good luck,

Bill

Comments for Compair L120SR showing "start inhibited"

Click here to add your own comments

Mar 27, 2011
Wrong direction
by: Mike

This fault has 2 possible causes.

1 - Initial power up with incoming phases transposed.

2 - *Excessive starting of the machine with SR motor overcurrent fault

* - This fault requires a code, which I can't find right now, to reset the fault.

L120SR is fitted with a Phase Monitor. This will prevent the compressor from starting if the rotation is incorrect. Switch any two leads at the disconnect or at main contactor to reverse direction.

If still not working call Compair for assistance.

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Compair Compressor Issues.

service manual for compair holman compressor needed

This is powered by a
ford diesel eng when it runs it dumps oil from the bottom were the engine and compressor join, could this just be the gasket or is this area under pressure when it runs and may be a seal on the rotor no oil comes out of the compressor at the outlets this model is a RO175 Have had no luck sourcing a new gasket for the joint any help would be great Thanks Mick

Click here to post comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Compair Compressor Issues.

CompAir - supplier for parts and filterss/dryers?

by Chito Condes
(Al Khobar, Saudi Arabia)

Dear Bill,
I have two (2) units of CompAir Luchard air compressors and other accessories that make up the start air storage and delivery system. Here are the specs:
Model: VMHD500
Serial No. H012-02020
Rated Pressure: 17.5 bars
Speed: 735 RPM
Cooling System: water
Oil Lubricated
Wycombe, England
Manufacturing Year: 1993
Motor Specs:
KW: 132
Volts: 380/400
RPM: 239
Leroy Somer
Air Filter: PR -2900

I would appreciate if you can help me find a supplier for parts and filterss/dryers.

The two (2) units air compressors and associated equipment were installed in 1993 for the engine test cell facility here in Saudi Arabia. Since then these were never used. Now we intend to commission the start air storage and delivery system. I would appreciate it very much if you can guide me on the proper way to recommission the system.
Best Regards,
Chito
Email: chitocondes@yahoo.com

Click here to post comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Compair Compressor Issues.