Compair 6025C2 Runs But Wont Build Pressure

by John
(Tacoma Wa)

Compressor will run in continuous mode, but will not build pressure. When I switch over to auto mode it shuts down after a second and the standby light goes on. Any help is appreciated.

Comments for Compair 6025C2 Runs But Wont Build Pressure

Click here to add your own comments

Jul 24, 2016
Thanks for the help
by: John

Would the load solenoid be the same as the pressure switch? And why the seconds timer and not the minutes timer? Thanks for the help.

Jul 22, 2016
Hmmmm - Compair 6025C2
by: Carl

Avelair don't make them, Compair (who are now Gardner Denver) do.
It seems that your load solenoid may be at fault, to test it, make sure you have the correct voltage going to it whilst it's activated (on load)
Failing that then it's possible that the timer may be at fault? The (seconds) timer may not be letting it go from star to delta so not going on load.
Let me know how you get on


Jul 20, 2016
by: Doug in

Avelair may have made it, but they don't support it, as far as I know today.

If you can post pix, maybe we can help, anyway.

Failing that, at least a description.