clarke air industrial compressor wont start sometimes, but sometimes it does??
by Matthew fricker
Hi,
I have a clarke air industrial 150l piston compressor thats about a year and a half old, its worked perfectly untill today.
We noticed earlier that it was starting sluggishly, now it starts sluggishly sometimes and works fine, other times it turns once and the overheat switch cuts in and stops it, then it continues to do this for a few mins till it eventually starts fine again.
It cant be the cold as winter where i live has barely set it yet, and it ran last winter fine. Its wired in the same way it has always been and has Always worked fine.
I just cant understand how it works sometimes and not others. I would just like to add that it still starts sluggishly even when it does work and the psssshhhh sound is heard when it fills up.
It also doesnt work more times than it does.
Please help as soon as you can as im really stuck and i run a small car repair centre (uniquecustoms.co.uk) and we have a van to paint by end of week and this is my only compressor as the other 200l is dead too :(
ThAnks
Matthew
_______________________
Bill says...
Matthew, no change in power supply, nothing else pulling power from the same circuit sometimes when the compressor is trying to start? Make sure the power source is clean.
Turn off the compressor, dump all the air from the tank, close the tank drain, and start the compressor. Any change? If it starts fine with no air, I suspect a sticking unloader valve or perhaps the pressure switch is not tripping fully or properly, and the unloader isn't getting opened every time, or full power isn't flowing to the motor when it is supposed to.
Next guess... start capacitor, though I would expect that to be a constant problem rather than intermittent if it was failing.
Give us some feedback as a comment, please.
Cheers,
Bill