Check valves installed ?
by Roger Bates
(St. Johns, Michigan)
We have 4 air compressors in our shop, all are piped into one system. My question is should they have check valves installed to prevent one unit from pressuring another unit. 3 units are piston type one unit is screw type. The screw type is our main unit others turn on as more air is needed.
___________________
Bill says...
Roger, I would have a check valve installed in each of the lines from each compressor before they reach the common manifold. As you point out, you don't want air from a running compressor flowing back down the line to a stopped air compressor, which has it's unloader valve opened to atmosphere.
Cheers,
Bill