only builds up to 85 psi

by larry
(gates, tn., USA)

Central Pneumatic model 94667

Central Pneumatic model 94667

Compressor will only build up to 85 psi then shuts down and recycles. Where is pressure switch located? I don't see it listed in the manual! Could that be the problem? thanks!!

_______________
Larry, in the image I have uploaded, the pressure switch is the black box on the left of the pump.

Using your multi-meter, when the compressor stops at 85 PSI, determine if power is flowing through the switch to the pump.

If power is flowing, then it likely isn't the switch. If power is not flowing, that is, the pressure switch has shut off at 85 PSI, then it's likely the switch is failing, unless it was adjusted incorrectly.

Bill

Click here to post comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Central Pneumatic Model 94667 Compressor Issues.

tripping overload

by Tom
(PA)

centrai pneumatic 21 gallon vertical . unit tripsw overload in 2 minutes of running . I took off the air line to the tank or the air line to the pressure switch and the unit keeps running,but when I hook it back up to put air in tank it trips the reset in a couple of minutes. any ideas ? thanx Tom
___________________
Tom, I think your motor is overheating as a result of the increasing load of the air in the tank.

You indicate that it runs fine with no load.

There are a number of reasons for this including running a compressor with a too small extension cord, impeded intake air filter, intake valve or more likely pressure valve failing, the tank check valve is not working properly, mechanical failure of the pump or the motor.

I don't have sufficient information about your compressor to help you to the likely culprit. See the sitemap page and look under troubleshooting for pages with more tips.

Bill