Central Pneumatic 67501 motor hums and then shuts off

by Jim strouse
(Whitney, TX)

Completed checklist of all steps to start - still motor hums and then shuts off. After pushing reset button, try again and same result. Any ideas, pro? Thanks.

Comments for Central Pneumatic 67501 motor hums and then shuts off

Click here to add your own comments

May 22, 2017
67501 won't restart
by: Bill

Basically the same advice, William.

If you have clean power, no other devices pulling power from the same circuit, and with the 67501 plugged directly into a socket, then it sounds like a motor capacitor might be the issue.

Please see the troubleshooting pages on this site that address this specific compressor issue.

May 21, 2017
Will not automatic re- start
by: William

Same thing...

Motor hum and shut off, press reset, hum and shut off.

May 10, 2017
Central Pneumatic 67501
by: Bill

If you have clean power, no other devices pulling power from the same circuit, and with the 67501 plugged directly into a socket, then it sounds like a motor capacitor might be the issue, Jim.

See the page on this site about how to test your capacitor.