motor start/run capacitor is bad but part number/ value label is missing
_________________
Find out where your local Harbor Freight sends their air compressor warranty work. That shop should be able to help you. B.
Oct 16, 2011
Need Pressure Switch by: Randall
Where can I find a pressure switch for a CP air compressor model #40400
___________________
Harbor Freight sells the compressors. Logic would suggest they sell the pressure switches. However, look at the brand on the switch. You may find that it's the same switch as on many other compressors, so you can pick one up at any of those outlets too.
Jul 05, 2010
Compressor 40400 will not start by: Gerry
I ran my compressor 40400 yesterday. Today it would not start. It has power to it and through the switch, I acn't find prob. Thank you, for helping me.
______________________________ Bill says...
Gerry, if you are getting power to the pressure switch, and then you have checked and you are getting full voltage through the switch, indicating that the pressure in the tank is at or below the cut in pressure level and the pressure switch has tripped, then power is getting to the motor.
When you turn the compressor on, does anything happen at all... any click, any noise?
If nothing happens at all, and power is getting to the start capacitor on the motor, then I'd be checking that or the motor itself.
Cheers,
Bill
Jul 03, 2010
Air Leaking from the Air Pressure Switch by: Luis, L.
My compressor was working fine but lately it was not building pressure and I could hear an air leak coming from the Air Pressure Switch. I have not taken the switch apart to see what is wrong. Has anybody experience this problem? Is there anything that I can accomplish by taking this switch apart?
When I start the 40400 compressor it runs normally at a high speed for a few moments, but when the pressure reads about 18 PSI it starts to lug down and sometimes quits. The motor no longer just stops clean, it seems to be drawing lots of electricity (based on my dimmer lights) and sounds like the motor is under a heavy load. I was concerned that I would smoke the motor so unplugged it. About 30 seconds later I hear something like a valve move. I plugged it back in and the same thing happened again. Any idea what the problem is? As it is I cannot use the compressor. Thanks Sky
Jun 02, 2010
Oil leak by: Anonymous
I am noting oil leaking onto the tank and it appears to be coming from the motor drive. Are there troubleshooting tips for this? Thanks Jim
_____________________________ Jim, mine is leaking too. It's a seal replacement issue, I'm sure. In my case, I just make sure the level of oil in the sump is as it should be, and wipe off the housing as necessary. I don't feel like spending any money repairing the leak.
Of course, if it's bad enough, it's time to take it to the shop.
Dec 21, 2009
Central Pneumatics Compressor #40400 by: Mike Nickerson