Pressure Switch - Can I run two legs of my 3 ph power

by Al McDaniel
(Newark, Oh)

Hi Bill,

You helped me with my check valve question and I am hoping that you can help me with my pressure switch question.

I forgot to order a Mag Switch for my compressor and I need to get it up and running temporarily.

Can I run two legs of my 3 ph power through the pressure switch to get up and running while I am waiting on the Mag Switch to in?

Thanks,
Al McDaniel

_____________________
Bill says....

Al, I don't know. The electrical side of higher voltage power is outside my ken.

However, your question is posted in electrical troubleshooting, and I hope someone will respond to you soon.

Cheers,

Bill


Click here to post comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Compressor Pressure Switch Problem.

Air compressor will not shut off at cut out pressure setting

by dwight hanks
(mauriceville texas)

condor mdr11 - my cutoff valve will pop out at desired pressure of 125 but will not kick off . i have to turn breaker of manually and shut of compressor. any clue as to why this happens thanks

i bought a new pressure switch for my air compresser but i still have same problem .

the pressure will build up to the 125lbs pressure but won't kick off.

the pop off valve will open and i have to shut breakers of to compressor and manually push pop off valve back in . appreciate any help . perhaps i have

it wired in wrong but don't think so. thanks for any help. can u show a wire diagram for my switch . it is a condor mdr11. its possible i have it wired wrong.
______________________
Dwight, what is the normal cut out pressure setting for your compressor? If the setting on the new pressure switch is higher than the PRV relief pressure, then the PRV is going to let go before the pressure switch "sees" the cut out pressure level.

You may be able to adjust the settings on the switch to lower the cut out pressure to below the PRV release pressure, though, 125 PSI seems low.

More info on your switch here:

w.condor-werke.de/en/product_catalogue/pressure_switches/pressure_switches.html

Cheers,

Bill


Click here to post comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Compressor Pressure Switch Problem.

Pressure switch for a automan direct drive 5 HP. single stage 230 volts 80 gal. tank (single phase)

by Walter
(Toledo,Ohio USA 43615)

The compresor itself runs fine however it will continue to run whereby causing the pressure relief valve to blow and I have to shut it down manualy.The points in the pressure box are burnt/pitted pretty good and I believe this to be the problem.However I don,t know if I can just purchace the contacts seperatly or if I should replace the entire box??? and where would be best bussiness to make this purchase/what should I expect to pay for the part?

____________________________
Bill says....

Yes Walter, from the sounds of it your PRESSURE SWITCH is pooched.

Dump the air, pull the power, remove the switch (making sure you label the wires as to where they were originally attached) and take the switch with you to the compressor / hardware store.

Make sure that if the present switch is toggling the unloader valve, that the new one you buy is similar in function.

I'm guessing somewhere between $25 and $50 should get you a new switch.

Cheers,

Bill

Click here to post comments