Atlas Copco ZR275 "Internal Failure 7002"

by Ron
(Burlington, WI USA)

The Elektronikon display gives me the fault message, "Internal Failure 7002".


I cannot find in any of our literature what that failure code means.

The Red LED "3" is on solid and the machine displays that error.

Comments for Atlas Copco ZR275 "Internal Failure 7002"

Click here to add your own comments

Sep 16, 2016
module location?
by: duane

Hi so are these "modules"contained within the control unit (dashboard)
we have a xas 375 cd6 that displays the same thing
thanks

Aug 04, 2016
7002 error
by: Paul

Hi This is a fault with the second support module or the connection to it from the master module. Change over the black connecting cables on support modules 1 and 2 to see if the fault changes. If it does then replace the black cable. If it doesn't then change the No2 support module.

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Atlas Copco Compressor Issues.