GA-75 VSD converter fault

by Mike
(Toronto Canada)

Our compressor will start but immediately will stop.


Error says converter failure.

I reset and start again and it runs perfectly all day until the next morning.

Its like something is sticking and frees up after first attempt to start.

Click here to post comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Atlas Copco Compressor Issues.

GA-75 Element Temperature ROTA Error

Hi,

I am facing the problem in my Atlas Copco GA-75 Air Compressor. It is showing the "Element Temperature Rota Error". Kindly help me that what could be the possible causes for this Error?

Comments for GA-75 Element Temperature ROTA Error

Click here to add your own comments

Sep 09, 2016
temp issue
by: Anonymous

we had to swap out 3 different oil temp valves to get one to work right. get the 60 deg one

Aug 27, 2016
rota
by: Doug in s.d.ca

Sounds like oil or oil circulation problem, causing high temp.

Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Atlas Copco Compressor Issues.

GA75: Peaks observed in current immediately after...

by Viral
(India)

Greetings of the day…

GA75: Peaks observed in current immediately after the delta changeover for fraction of seconds.

We have observed below during its changeover from UNLOAD to LOAD i.e. STAR to DELTA.

Compressor Motor: 75 KW with Star- Delta starter, c/o time is 10 sec from STAR to DELTA.

During Unload condition: Motor starting current is about 300-325 A and then it remains normal up to time period of 10sec i.e. 80-85 A.

From Unload to Load conditions i.e. after 10 sec, motor switches over from STAR to DELTA, during this period motor is taking higher current i.e. 1100-1200A which is abnormal.

Kindly help to solve the above mentioned by providing your valuable insights.

Best Regards.

Comments for GA75: Peaks observed in current immediately after...

Click here to add your own comments

Aug 13, 2016
Re:
by: Viral

Yes it is transient.

Thanx

Aug 12, 2016
star/delta
by: Doug in s.d.ca

Given the normal star current, doesn't seem likely.

I'm understanding that the high current after delta switch is transient, correct?
That would point to the switching relays, I think.

Aug 12, 2016
Re:
by: Viral

Thanx, any possibility of mechanical defect in compressor?

Aug 04, 2016
star/delta
by: Doug in s.d.ca

You should, if you haven't, verify that all connections under your control are solid - that is, tight, and not corroded. See if you see the spikes at the closest you can get to the source power. If the spikes are present at the near-source end, you may have to get your power company involved.

But, if the spike is more local, then you need to consider that there is a problem in the relays that do the switching on the compressor. They may be switching too fast causing excess arcing.

Aug 03, 2016
Re:
by: Viral

Yes it is observed for all the 03 phases.

A 415V common bus supplies to the Compressor and Control Room lighting, during the peaks there are observed dips in the lighting which led to further investigations.

Aug 01, 2016
star/delta in Atlas Copco GA75
by: Doug in s.d.ca

This is true for all 3 phases?

After the switch, what happens? IOW, what caused you to investigate?

Click here to add your own comments