919-16523 AIR COMPRESSOR BLOWS BREAKER

by Charlie
(Spring Hope NC)

I have a craftsman model 919-16523. It would build pressure 100+ the first time I plug it in. Then when the pressure goes down it clicks throws breaker. It works great the first time you start it but when it calls for it the second time it blows breaker. The motor turns free so I dont think it is motor. Any suggestions?


Charlie
_______________________
Bill says...

Charlie, try this. Identify the unloader valve as part of or near your pressure switch.

Drain the tank with the compressor off. Close the drain and start the compressor. Let it run up to normal cut out pressure?

When it shuts off, did the unloader valve work? Let me know as a comment here, if you would.

Cheers,

Bill

Comments for 919-16523 AIR COMPRESSOR BLOWS BREAKER

Click here to add your own comments

Apr 23, 2012
compressor blows breaker
by: jim

The one-way valve(check value) that keeps pressure off the compressor allowing it to restart without
a load against the compressor its self is bad.

Feb 08, 2012
It was the cap switch
by: IamYogiRam

On mine the plastic housing that holds the capacitor wasn't mounted at the bottom. There was a pressure plate in there that wasn't activating so the capacitor wasn't helping the motor to start.

Jan 25, 2012
blows breaker
by: charlie

Unloader valve good. Took the small line off that went to the unloader valve. Took some air out of the take and tried start compressor. Motor turn over couple more revolution than before breaker blowed. So took main line off from the tank and the motor turned over fine. So is the motor bad because it couldnt push valve down in the take once it has pressure in the tank.

________________

Charlie, you have eliminated the easy stuff. Now, you want to check out the motor start capacitor to see if it's working. See Electrical Issues on the site map page for a link.


Jan 24, 2012
blows breaker
by: charlie

Ok fired it up and it built up 100 pounds. I think I could hear the unlocker valve for second. Drained it and kept try at different pressures to get it running. Had to drain about all of it for it to run. Built it back up and started turning the motor by hand and it was very hard to turn it but I assume it is because of pressure in the tank. Or should it free spin. It like it has to much compression for the motor to turn over.

___________________
Charlie, be sure the unloader valve worked, as if it doesn't, that's likely your problem. This time, when you drain all the air, also remove the line from the top of the pump to the tank, remove and clean the check valve at the tank, then reassemble and check. But, first, be sure that the unloader valve is working.


Click here to add your own comments

Add your own question or comment. It's easy to do. How? Simply click here to return to Craftsman Compressor Issues.

craftsman professional - bogs out then trips breaker

by gerry
(las vegas,nv)

horizontal tank on it.. has 2 capacitors on top of motor.. when i plug it in fills up to about 45lbs and bogs out then trips breaker on motor.. think it might be wired wrong but missing wiring diagram on motor.. CAN YOU HELP??????
_______________________
Gerry, Sears has an excellent parts depot, and you may be a manual there.

www.searspartsdirect.com

See the troubleshooting section on the site map page for information about what causes an air compressor to lug and pop breakers.

Make sure your power supply is clean, and you are not using an extension cord.

Cheers,

Bill

Comments for craftsman professional - bogs out then trips breaker

Click here to add your own comments

Sep 11, 2013
im having the same problem
by: Darrick

how do i fix this?
__________________
Depends on which of the compressor problems that commonly cause this is creating the problem on your air compressor.

Read all of the postings on the subject, and then add a comment here telling us what you found.