47065 not run more than 1 or 2 minutes before tripping

by Jeremy


My 47065 will run for about a minute or two and then shut off. If I wait and then press the black (circuit breaker?) button it will run again for another minute or two. If I bypass the "circuit breaker" it will continue running to 120PSI as it's supposed to. I have checked the amperage draw while doing this and it's near 17 amps that the unit is drawing. The unit is rated for 14.6 amps continuous. Off the top of my head I'm guessing the brushes in the motor need replacing. Does this sound correct to you? And if so, are the brushes easily replaceable on this motor. Any idea what size and spec brushes I need and where I can find them? Thanks.

Comments for 47065 not run more than 1 or 2 minutes before tripping

Click here to add your own comments

Aug 23, 2016
Same here
by: Chris

I re-ran better guage wire to the caps which check fine w/a Huntron 2000 tracker/both good.I want to replace the units Ckt Bkr 20amp sound good??/ the mnl is useless , it says P/N 35B Over Load Switch

Jun 29, 2015
47065 tripping breaker
by: Bill

According to the manual I have the 47065 is powered by a 3 HP Working / 120 Volt / 60 Hz / Single Phase / 12 Amp motor.

Before I started tearing down the motor to check brushes, assuming your motor actually has them, it were my compressor I'd be checking both the start and run capacitors first. See the page on this site about how to do that.